Define the cooling channels
Define all the cooling channels, and identify inlets and outlets for each channel.
-
Use Ctrl-click to select all the cooling channels in the model as shown.
-
In the Channels card, click add
to categorize the selections as channels.
- Enable the Inlet/outlet Selection Mode to define the inlets and outlets for the channels.
-
In the display window, for each cooling channel, click the corresponding inlet
surface as shown in the following figure to designate it as the inlet.
-
In the display window, for each cooling channel, use Shift-click to select the
corresponding outlet surface as shown in the following figure to designate it as
the outlet.
The channel inlet and outlets are listed under the channels list. To remove an incorrect surface definition, click Remove body.
- In the Inlet Temperature, keep the default value of 25° C.